NAAC ENERGY CONTROLS (P) LIMITED
Home Page  
Company Profile  
Showroom  
    Power Factor Correction & Harmonic Filter
    Power Quality Management
    Active Comp. PF / Harmonic Filter System
Life Line Series PF Compensator
To inquire, Select Product/s & Click on

Product Code : NAAC-08

[Select]
Product Specification
Life Line Series PF Compensator:
  • Compact wall mounting series for small to medium industries.
  • Available upto 1000 KVAR rating.
  • Suitable for both balanced and unbalanced load.
  • Advanced 3 phase controller with inbuilt load analyzer.
  • Axial flow fan controlled through thermostat.
  • Upto 3 year warranty with long life LL-10 Capacitors.
NAAC P.F. Compensator series the power range goes from 12.5 kvar to 100 kvar. They are designed for small to medium load networks. They are highly reliable, cost effective solution for maintaining high network power factor.

They are ultimate solution for compensation of unbalanced loads. The compensation is released by measuring the reactive power of the system, through 3 CTs from all 3 phases. This makes it best suited even for most unbalanced loads apart from balanced loads.

They come equipped with following outstanding features:
  • Incomer TP MCCB 35kA
  • Micro processor based Neptune Phasetrac range of 3 phase Controller
  • Inbuilt 3 phase Analyzer
  • Compact wall mounting series with zinc passivated side clamps
  • Front louvers with Axial flow fan and thermostat
  • Heavy duty specially designed Neptune capacitor duty contractors with high thermal current withstand capacity
  • MCBs for control circuit protection
  • HRC fuse or MCB (Series-D) for backup protection of capacitor banks
  • High electrolytic grade aluminium Busbar installed on SMC TP supports
  • Discharge resistors (MOR)
  • Standard 1 year warranty with NSL-10 Capacitor or 3 year warranty with long life LL-10 Mono 16 Capacitors
  • Powder coated - RAL 7035, Structure finish
General Characteristics:
Control Module with Data Logger:
  • Measurement of A, V, PF, Cos phi, W, VAR, VA (sigma W, sigma VA, sigma var etc.)
  • Sense 1 % of load current.
  • Auto/Manual mode selection with indicator light.
  • Automatic calculation of C/k value.
  • Program entry for targeted Cos phi value.
  • Number of capacitor steps are user definable. The consequent switching time between capacitor steps is adjustable from 2 to 50 seconds.
  • C+/NORMAL/C- condition lights indicate actual system state.
  • Over Voltage, Insufficient Compensation, Over Compensation state, alarm indicator lights with output contact.
  • Adjustable programmable Over Voltage protection for capacitor banks.
  • Micro Controller based digital design complying with international standards.
  • Flush mounting with rear panel connectors.
  • Designed to use with Current Transformer (.../5A).
Electrical & General Characteristics:
  • Power range: 12.5 - 1 00 KVAR (440V)
  • Mains voltage (working voltage): standard 440V (other voltage on request)
  • Rated frequency: 50 Hz
  • Altitude: less than or equal to 2000 m a.s.l.
  • Relative humidity: 90% max. at 35oC
  • Duty: continuous
  • Temperature class: 25 + 55oC
  • Power supply line: Three phase + ground + netural (for 440V mains version only)
  • Relay current input signal: from CT on line..../5A
  • Relay voltage input signal: picked up internally
Installation:
  • Indoors, wall-mounted, in ventilated, non-­dusty environment, away from direct sunlight.
  • Cable inlet from top
Disconnecting Switch:
  • TPMCCB-35kA breaking capacity
Mechanical Structure:
  • The basic structure is made of white CRCA steel sheet with mounting plate Zinc galvanized.
  • The outer steel structural work is painted with cleaning treatment, degreasing, phosphating 70mm thickness paint with epoxy powder colour RAL7035.
  • Louvers on front door with Axial Flow Fan.
  • Capacitor mounted on side openable section from outside - offering easy replacement.
Wiring & Busbar:
  • HR Copper wires are used for all the wiring connecting to Electrolytic grade Cu./AI. Busbar section.
Fuses/ MCBs for Backup protection:
  • HRC Fuse Link with base
  • The fuses are of 80kA breaking capacity
  • Series-D TP MCBs for backup protection (optional)
Contactors:
  • Equipped with Heavy Duty Capacitor Duty Contactor with early make contacts.
  • Coil voltage 230V, 50-60Hz.
Capacitors:
  • Series NSL-1 0 Floppy Cap singIe-ph. elements wired in a delta connection rated 450V.
  • Optionally Long Life LL-10 Mono 16 Series Capacitors, rated 450V.
Protection Devices:
  • Each capacitor bank is equipped with discharge devices capable of reducing the residual voltage to below 10% of the rated capacitor voltage in about 30 seconds.
Other Products
Harmonic System for Industries
Harmonic System for Industries
Harmonic System for Office
Harmonic System for Office
Energy Saving & Energy Management Software
Energy Saving & Energy Management Software
Life Line Series Detuned Catalogue
Life Line Series Detuned Catalogue
Energy Management
Energy Management
Energy Saving Management
Energy Saving Management
 
<< Back
CONTACT DETAILS
C-135 Hosiery Complex, Phase II (Extn.),Noida - 201305, Uttar Pradesh, India
Phone:91-120-4221631-34
Fax:91-120-4221635
Send Mail     
Key Personnel
Mr. Chander M. Kapoor (Director)
Mobile:+919811199085
  
Copyright © 2006 tradeindia.com. All Rights Reserved. Designed & Developed by