Energy Saving & Energy Management Software - Manufacturer, Service Provider, Noida, India
NAAC ENERGY CONTROLS (P) LIMITED
Home Page  
Company Profile  
Showroom  
    Power Factor Correction & Harmonic Filter
    Power Quality Management
    Active Comp. PF / Harmonic Filter System
Energy Saving & Energy Management Software
To inquire, Select Product/s & Click on

Product Code : M-2000

[Select]
Product Specification
Energy Saving & Energy Management:
  • Advanced (cycle by cycle) Electrical Network Analysis
  • Complete network harmonics analysis, upto 63rd H armonic
  • High visibility, 5" graphics LCD screen with backlight
  • Display neutral voltage and current
  • Com pretensive data logging
  • Feeder transformer analysis
  • Compliance monitoring of inter nation power quality standards
  • Flexible design, allows system customization
  • Upto 20-48 KB of flash memory
  • user friendly PC software (Power Monitoring Software)
  • A variety of isolated digital and analog inputs and outputs
  • Multiple communication protocols
  • Menu driven operation
  • Easy installation, configuration and use
Features:
Metered Values:
  • True RMS measurements
  • Advanced, real-time, cycle by cycle measurements, at 128 samples per cycle. Real-time values averaged over 8 through 256 cycles for easy reading.
  • Choice of models ranging from essential measurements only (Volts, currents, frequency and powers) to over 2000 electrical parameters.
  • Min/Max. values.
  • Four quadrant readings (power, power factor)
  • Displays neutral voltage and current.
Time-of-use (TOU):
  • Time-of-Use informations is automatically stored for each predefined period
  • Power Monitoring Software calculates electricity costs according to varying tariffs (based on time, season etc.)
Power Quaility:
  • Waveform display and capturing, at 128 samples per cycle
  • Harmonics analysis, up to 63rd harmonic (individual, TRD, K and crest factors)
  • Sag/Swell recording (magnitude, duration and trigger events)
Large Digit Screen:
Permits simultaneous display of 9 parameters: 3 measured values plus 3 minimum and 3 maximum. Parameters can be mixed, such as average voltage, current and power factor. This unique feature allows analysis of the foremost parameters at a glance, without touching the unit. The PU % buttons displays the values as a percentage from their nominal rating.

Waveform Screen:
128 samples/cycle
This large graphic display allows easy monitoring of transients of 130/156muS (at 60/50Hz). The display includes detailed information for each wave: the type and phase, THO, RM8, peak & bottom values plus value at cursor position.

Harmonics Screen:
63 harmonics
The graphic display enables inspection of the harmonics pollution at a glance. The display includes detailed information for each harmonic: type, phase, number of the harmonic, the value in amperes/volts and in percent, the angle and the frequency.

Harmonics Analysis:
Displays the harmonics spectrum both as a graph and as a table, in addition to harmonics analysis parameters (THD, K-Factor and Crest-Factor). Compliance monitoring of international power quality standards, such as IEEE-519, allows easy network analysis.

Specifications:

LCD Display Size 94x76 mm
LCD Display Resolution Graphic 160x128 pixels
LCD Display Type FSTN, LED backlight
Overall Dimensions 144 x 144 x 120 mm [H x W x D]
Panel Cutout 138 x 138 mm
Weight 1.4 kg
Ambient Temperature -20oC - +55oC
Storage Temperature -25oC - +65oC
Direct Voltage Measurement 347/600 VAC Max.
Current Measurement ../5A (1A)
Relay Alarm Max. 2A 250 VAC
EMC Compatibility EN61000-4-2/3/4/5,
ENV50204 , ENV50141
Safety Standards EN61010-1, EN50439-1, UL508
Protection Class IP40
Analog Channels 7
4 x Voltage Channels
3 x Current Channels
Communication (optional) Neptune (Protocol), Mod Bus RTU
Power Supply 110 or 230v, 50/60 Hz
Power Consumption 15 VA
Harmonics Analysis 1 through 63rd

Model Information:

Options
   Product Series    Displayed Phases Accur. (%)
(FS), 1 dgt
1
2
3
4
Full Instrumentation












Wiring Diagnostics
ANSI C12.1 Accuracy
Frequency




Current, per Phase




L1, L2, L3, Avg
0.1
Current, Neutral




N
0.2
Current, L-to-L (Transformer)




L12, L23, L31, Avg
0.2
Volts, L-to-L




L12, L23, L31, Avg 0.2
Volts, L-to-N




L1, L2, L3, Avg 0.2
Volts, Neutral 




N
0.2
Real Power (kW)




L 1, L2, L3, Sum 0.4
Reactive Power (kVAr)




L 1, L2, L3, Sum 0.4
Apparent Power (kVA)




L 1, L2, L3, Sum 0.4
Power Factor




L 1, L2, L3, Sum 0.4
Time-of-Use (TOU):


  • Real Energy (kWh)




Sum 0.5
  • Reactive Energy (kVArh)




Sum 0.5
  • Energy Accumulation Modes: in, out, net, total






THD (Current, Volts, L- tool and L- to-N)






L 1, L2, L3, Avg, N 
0.2
K-Factor (Current, Volts, L- tool and L- to-N)



L 1, L2, L3, Avg, N 
0.2
Harmonics (Current, Volts, L-to-L and L- to-N)



L 1, L2, L3, N 
0.2
Waveforms (Current, Volts, L- tool and L- to-N)



L 1, L2, L3, N
0.2
Min/Max Readings






Event Logging (coming soon)



Data Logging (coming soon)



Data / Time Stamping






Flash Memory (Kilo Bytes)
256 512 512 1024

Maximum Flash Memory (Kilo Bytes) 256 1024 1024 2048

RS-422 / 485 Communication Port - Neptune Protocol





Other Products
Life Line Series PF Compensator
Life Line Series PF Compensator
Energy Management
Energy Management
Harmonic System for Office
Harmonic System for Office
Energy Saving Management
Energy Saving Management
Naac Power Saver
Naac Power Saver
Life Line Series Detuned Catalogue
Life Line Series Detuned Catalogue
 
<< Back
CONTACT DETAILS
C-135 Hosiery Complex, Phase II (Extn.),Noida - 201305, Uttar Pradesh, India
Phone:91-120-4221631-34
Fax:91-120-4221635
Send Mail     
Key Personnel
Mr. Chander M. Kapoor (Director)
Mobile:+919811199085
  