Energy Saving & Energy Management Software - Manufacturer, Service Provider, Noida, India
NAAC ENERGY CONTROLS (P) LIMITED
Home Page
Company Profile
Showroom
Power Factor Correction & Harmonic Filter
Power Quality Management
Active Comp. PF / Harmonic Filter System
Energy Saving & Energy Management Software
To inquire, Select Product/s & Click on
Product Code :
M-2000
[Select]
Product Specification
Energy Saving & Energy Management:
Advanced (cycle by cycle) Electrical Network Analysis
Complete network harmonics analysis, upto 63rd H armonic
High visibility, 5" graphics LCD screen with backlight
Display neutral voltage and current
Com pretensive data logging
Feeder transformer analysis
Compliance monitoring of inter nation power quality standards
Flexible design, allows system customization
Upto 20-48 KB of flash memory
user friendly PC software (Power Monitoring Software)
A variety of isolated digital and analog inputs and outputs
Multiple communication protocols
Menu driven operation
Easy installation, configuration and use
Features:
Metered Values:
True RMS measurements
Advanced, real-time, cycle by cycle measurements, at 128 samples per cycle. Real-time values averaged over 8 through 256 cycles for easy reading.
Choice of models ranging from essential measurements only (Volts, currents, frequency and powers) to over 2000 electrical parameters.
Min/Max. values.
Four quadrant readings (power, power factor)
Displays neutral voltage and current.
Time-of-use (TOU):
Time-of-Use informations is automatically stored for each predefined period
Power Monitoring Software calculates electricity costs according to varying tariffs (based on time, season etc.)
Power
Quaility:
Waveform display and capturing, at 128 samples per cycle
Harmonics analysis, up to 63rd harmonic (individual, TRD, K and crest factors)
Sag/Swell recording (magnitude, duration and trigger events)
Large Digit Screen:
Permits simultaneous display of 9 parameters: 3 measured values plus 3 minimum and 3 maximum. Parameters can be mixed, such as average voltage, current and power factor. This unique feature allows analysis of the foremost parameters at a glance, without touching the unit. The PU % buttons displays the values as a percentage from their nominal rating.
Waveform Screen:
128 samples/cycle
This large graphic display allows easy monitoring of transients of 130/156muS (at 60/50Hz). The display includes detailed information for each wave: the type and phase, THO, RM8, peak & bottom values plus value at cursor position.
Harmonics Screen:
63 harmonics
The graphic display enables inspection of the harmonics pollution at a glance. The display includes detailed information for each harmonic: type, phase, number of the harmonic, the value in amperes/volts and in percent, the angle and the frequency.
Harmonics Analysis:
Displays the harmonics spectrum both as a graph and as a table, in addition to harmonics analysis parameters (THD, K-Factor and Crest-Factor). Compliance monitoring of international power quality standards, such as IEEE-519, allows easy network analysis.
Specifications:
LCD Display Size
94x76 mm
LCD Display Resolution
Graphic 160x128 pixels
LCD Display Type
FSTN, LED backlight
Overall Dimensions
144 x 144 x 120 mm [H x W x D]
Panel Cutout
138 x 138 mm
Weight
1.4 kg
Ambient Temperature
-20
o
C - +55
o
C
Storage Temperature
-25
o
C - +65
o
C
Direct Voltage Measurement
347/600 VAC Max.
Current Measurement
../5A (1A)
Relay Alarm
Max. 2A 250 VAC
EMC Compatibility
EN61000-4-2/3/4/5,
ENV50204 , ENV50141
Safety Standards
EN61010-1, EN50439-1, UL508
Protection Class
IP40
Analog Channels
7
4 x Voltage Channels
3 x Current Channels
Communication (optional)
Neptune (Protocol), Mod Bus RTU
Power Supply
110 or 230v, 50/60 Hz
Power Consumption
15 VA
Harmonics Analysis
1 through 63rd
Model Information:
Options
Product Series
Displayed Phases
Accur. (%)
(FS), 1 dgt
1
2
3
4
Full Instrumentation
Wiring Diagnostics
ANSI C12.1 Accuracy
Frequency
Current, per Phase
L1, L2, L3, Avg
0.1
Current, Neutral
N
0.2
Current, L-to-L (Transformer)
L12, L23, L31, Avg
0.2
Volts, L-to-L
L12, L23, L31, Avg
0.2
Volts, L-to-N
L1, L2, L3, Avg
0.2
Volts, Neutral
N
0.2
Real Power (kW)
L 1, L2, L3, Sum
0.4
Reactive Power (kVAr)
L 1, L2, L3, Sum
0.4
Apparent Power (kVA)
L 1, L2, L3, Sum
0.4
Power Factor
L 1, L2, L3, Sum
0.4
Time-of-Use (TOU):
Real Energy (kWh)
Sum
0.5
Reactive Energy (kVArh)
Sum
0.5
Energy Accumulation Modes: in, out, net, total
THD (Current, Volts, L- tool and L- to-N)
L 1, L2, L3, Avg, N
0.2
K-Factor (Current, Volts, L- tool and L- to-N)
L 1, L2, L3, Avg, N
0.2
Harmonics (Current, Volts, L-to-L and L- to-N)
L 1, L2, L3, N
0.2
Waveforms (Current, Volts, L- tool and L- to-N)
L 1, L2, L3, N
0.2
Min/Max Readings
Event Logging (coming soon)
Data Logging (coming soon)
Data / Time Stamping
Flash Memory (Kilo Bytes)
256
512
512
1024
Maximum Flash Memory (Kilo Bytes)
256
1024
1024
2048
RS-422 / 485 Communication Port - Neptune Protocol
Other Products
Life Line Series PF Compensator
Energy Management
Harmonic System for Office
Energy Saving Management
Naac Power Saver
Life Line Series Detuned Catalogue
<< Back
CONTACT DETAILS
C-135 Hosiery Complex, Phase II (Extn.),Noida - 201305, Uttar Pradesh, India
Phone:
91-120-4221631-34
Fax:
91-120-4221635
Send Mail
Key Personnel
Mr. Chander M. Kapoor (Director)
Mobile:
+919811199085
Copyright © 2006
tradeindia.com
. All Rights Reserved.
Designed & Developed by